Overview

The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection curret.The tolerance according to IEC60691 is from +0 to-10℃.(With Japan Electrical Appliance and Material Law,on the other hand,they must function in the tolerance range of ±7℃.).

Details

 

10A- BF Series
New Model No Rated functioning temp
(Tf)
Fusing-off temperature Holding temperature(Th) Maximum temp. limit(Tm) Rated current(Ir) Rated voltage(Ur) Safety approval RoHS
Compliace
UL VDE PSE CCC
BF73 73℃ 70±2℃ 45℃ 150℃ 10A 250Vac
BF77 77℃ 76+0/-4℃ 51℃ 150℃ 10A 250Vac
BF84 84℃ 82±2℃ 58℃ 150℃ 10A 250Vac
BF94 94℃ 91±3℃ 66℃ 150℃ 10A 250Vac
BF99 99℃ 96±2℃ 71℃ 150℃ 10A 250Vac
BF104 104℃ 100±2℃ 79℃ 150℃ 10A 250Vac
BF113 113℃ 109+3/-1℃ 84℃ 150℃ 10A 250Vac
BF117 117℃ 115±2℃ 92℃ 160℃ 10A 250Vac
BF121 121℃ 119+2/-3℃ 94℃ 160℃ 10A 250Vac
BF133 133℃ 129±2℃ 104℃ 160℃ 10A 250Vac
BF142 142℃ 139+2/-3℃ 114℃ 160℃ 10A 250Vac
BF157 157℃ 152±2℃ 127℃ 172℃ 10A 250Vac
BF172 172℃ 169+3/-1℃ 144℃ 189℃ 10A 250Vac
BF184 184℃ 182+1/-3℃ 159℃ 210℃ 10A 250Vac
BF192 192℃ 188±3℃ 170℃ 250℃ 10A 250Vac
BF216 216℃ 214+2/-3℃ 191℃ 380℃ 10A 250Vac
BF229 229℃ 226+3/-2℃ 200℃ 250℃ 10A 250Vac
BF240 240℃ 235±3℃ 200℃ 300℃ 10A 250Vac

 

Rated functioning temperature(Tf)
The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection curret.The tolerance according to IEC60691 is from +0 to-10℃.(With Japan Electrical Appliance and Material Law,on the other hand,they must function in the tolerance range of ±7℃.).
Fusing(cut)-off temperature
The fusing-off temperature indicates value measured in silicon oil with a temperature increased by 0.5-1℃ per minute and a detective current 100mA or less.
Holding temperature(Th)
The maximum temperature at which a thermal Cutoff will not cause a change in state of conductivity to open circuit while conducting rated current for 168 hours. This rating is required by safety standards based on IEC60691.
Maximum temperature limit(Tm)
The maximum temperature at which a Thermal Cutoff can be maimtained for 10 minutes without reclosing.This rating is requirde by safety standards based on IEC60691.
Rated current(Ir) The allowable maximum current which a Thermal Cutoff is able to carry.
Rated current(Ur) The allowable maximum voltage which a Thermal Cutoff is able to be applied.