Overview
The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection curret.The tolerance according to IEC60691 is from +0 to-10℃.(With Japan Electrical Appliance and Material Law,on the other hand,they must function in the tolerance range of ±7℃.).
Details
10A- BF Series | |||||||||||
New Model No | Rated functioning temp (Tf) |
Fusing-off temperature | Holding temperature(Th) | Maximum temp. limit(Tm) | Rated current(Ir) | Rated voltage(Ur) | Safety approval | RoHS Compliace |
|||
UL | VDE | PSE | CCC | ||||||||
BF73 | 73℃ | 70±2℃ | 45℃ | 150℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF77 | 77℃ | 76+0/-4℃ | 51℃ | 150℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF84 | 84℃ | 82±2℃ | 58℃ | 150℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF94 | 94℃ | 91±3℃ | 66℃ | 150℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF99 | 99℃ | 96±2℃ | 71℃ | 150℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF104 | 104℃ | 100±2℃ | 79℃ | 150℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF113 | 113℃ | 109+3/-1℃ | 84℃ | 150℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF117 | 117℃ | 115±2℃ | 92℃ | 160℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF121 | 121℃ | 119+2/-3℃ | 94℃ | 160℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF133 | 133℃ | 129±2℃ | 104℃ | 160℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF142 | 142℃ | 139+2/-3℃ | 114℃ | 160℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF157 | 157℃ | 152±2℃ | 127℃ | 172℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF172 | 172℃ | 169+3/-1℃ | 144℃ | 189℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF184 | 184℃ | 182+1/-3℃ | 159℃ | 210℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF192 | 192℃ | 188±3℃ | 170℃ | 250℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF216 | 216℃ | 214+2/-3℃ | 191℃ | 380℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF229 | 229℃ | 226+3/-2℃ | 200℃ | 250℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
BF240 | 240℃ | 235±3℃ | 200℃ | 300℃ | 10A | 250Vac | ● | ● | ● | ● | ● |
Rated functioning temperature(Tf): |
The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection curret.The tolerance according to IEC60691 is from +0 to-10℃.(With Japan Electrical Appliance and Material Law,on the other hand,they must function in the tolerance range of ±7℃.).
|
Fusing(cut)-off temperature: |
The fusing-off temperature indicates value measured in silicon oil with a temperature increased by 0.5-1℃ per minute and a detective current 100mA or less.
|
Holding temperature(Th): |
The maximum temperature at which a thermal Cutoff will not cause a change in state of conductivity to open circuit while conducting rated current for 168 hours. This rating is required by safety standards based on IEC60691.
|
Maximum temperature limit(Tm): |
The maximum temperature at which a Thermal Cutoff can be maimtained for 10 minutes without reclosing.This rating is requirde by safety standards based on IEC60691.
|
Rated current(Ir): | The allowable maximum current which a Thermal Cutoff is able to carry. |
Rated current(Ur): | The allowable maximum voltage which a Thermal Cutoff is able to be applied. |