33A-CR

Overview

(1) CONTACT TYPE : Contact Opens When Temperature
Rises To Set Point; (Normally Closed)
(2) CAP TYPE : C Cap
(3) TERMINAL ORIENTATION : Vertical
(4) TERMINAL SIZE: Amp#250 TAB ( 6.35mm x 0.8t mm )

HW H2 Series –
We can customize this bimetal thermostat according to client’s needs. This snap action temperature switch in three single-pole, single-throw (SPST) switch actions:

Automatic Reset – either open or close its contacts on temperature rise.

Manual Reset – Available with contacts that open on temperature rise. The contacts must be reset by pressing the button after the device cools down.

One shot – Available with contacts that open on temperature rise, and which never reclose unless the ambient temperature drops below -35°C.

For clients who wish to have action temperature above 180°C, we’d recommend our ceramic thermostat H2 series.

Details

Specification:

1.Standards according : GB14536.1-1998 , GB14536.10-1996 , JB/T3751-1997
2.Operation Temp: 16A/125V 0℃~230℃ ; 16A/250V 45℃~210℃
3.Resistance between terminals: below 50 m Ohm at DC5V/0.25A (initial figure).
4.Insulated resistance : above 100M Ohm (DC500V) at charged and non-charged portion.
5.Dielectric strength : AC1500V for 1 second at charged and non-charged portion.
6.Compliance : UL, VDE
7.For example:
Type
Off temp.
(C)
On.temp.
(C)
Contact
state
Dielectric
rating
H2/33-230/200/113BH2
230+/- 8
200+/-12
N.C.
250V/125V/10A