33A-HF2

Overview

(1) CONTACT TYPE : Contact Opens When Temperature Rises To Set Point
(Normally Closed)
(2) BRACKET TYPE : Hexagon shape Brass stud mounting
(3) TERMINAL ORIENTATION : Horizontal
(4) TERMINAL SIZE: Amp#250 TAB ( 6.35mm x 0.8t mm )
HW H2 Series –

We can customize this bimetal thermostat according to client’s needs. This snap action temperature switch in three single-pole, single-throw (SPST) switch actions:

Automatic Reset – either open or close its contacts on temperature rise.

Manual Reset – Available with contacts that open on temperature rise. The contacts must be reset by pressing the button after the device cools down.

One shot – Available with contacts that open on temperature rise, and which never reclose unless the ambient temperature drops below -35°C.

 

For clients who wish to have action temperature above 180°C, we’d recommend our ceramic thermostat H2 series.

Details

*Electrical Rating: 15A/125V AC 10A/250V AC
*Operation Temp: 16A/125V 0℃~230℃ ; 16A/250V 45℃~210℃
*Differential:10K~80K(Standard15K)
*Calibration Method:1℃/min. Air circulation furnace
*Temp. Tolerance: ±3K / ±5K / 8K
*Heat Durability: 220℃ MAX.
*Circuit Resistance:50 mΩ MAX.
*Insulation Resistance: 100MΩ min. at DC 500V
*Dielectric Strength:AC1000V for One Minute or AC 1800V for One Second(Leak current:0.5mA)
*Operation life:100,000 Cycles(15A 125V AC / 10A 250V AC)