Overview

(1) CONTACT TYPE : Contact Opens When Temperature Rises To Set Point (Normally Closed)
(2) CAP TYPE : C Cap
(3) TERMINAL ORIENTATION : Horizontal
(4) TERMINAL SIZE: Amp#250 TAB ( 6.35 mm x 0.8t mm )

Details

*Electrical Rating: 16A/250V AC 15A/125V AC 10A/250V AC
*Operation Temp: 0℃~180(VDE) ;50℃~205℃(UL/CUL)
*Differential:10K~30K
*Calibration Method:1℃/min. Air circulation furnace
*Temp. Tolerance: ±3K / ±5K
*Heat Durability: 180℃*2Hr MAX.
*Circuit Resistance:50 mΩ MAX.
*Insulation Resistance: 100MΩ min. at DC 500V
*Dielectric Strength:AC1000V for One Minute or AC 1800V for One Second(Leak current:0.5mA)
*Operation life:100,000 Cycles(15A 125V AC / 10A 250V AC) ; 10,000 Cycles(16A 250V AC)

Honest-Well Bimetal thermal switch T23 Series –

We can customize this bimetal thermostat according to client’s needs. This snap action temperature switch in three single-pole, single-throw (SPST) switch actions:

Automatic Reset – either open or close its contacts on temperature rise.

Manual Reset – Available with contacts that open on temperature rise. The contacts must be reset by pressing the button after the device cools down.

One shot – Available with contacts that open on temperature rise, and which never reclose unless the ambient temperature drops below -35°C.

 

For clients who wish to have action temperature above 180°C, we’d recommend our ceramic thermostat H2 series.