Overview
(1) CONTACT TYPE : Contact Opens When Temperature Rises To Set Point (Normally Closed) and it can only be reset by pressing the Manual button.
(2) CAP TYPE : D Cap ( Stainless Steel )
(3) TERMINAL ORIENTATION : Horizontal
(4) TERMINAL SIZE: Amp#250 TAB ( 6.35mm x 0.8t mm )
Details

Reset Type
|
Manual
|
Contact Type on Rise
|
NC
|
Electrical Rating
|
15A/125VAC
|
Calibration Method
|
1°C/min, Air circulation furnace
|
Operating Temp. *
|
40°C~ 205°C (UL/CUL)
|
Differential
|
10K ~ 65K
|
Temp. Tolerance
|
±3K/ ±5K
|
Heat Durability
|
180°C * 2Hr Max.
|
Circuit Resistance
|
50 MΩ Max.
|
Insulation Resistance
|
100MΩ at DC 500V
|
Dielectric Strength
|
AC 1000V/min or AC 1800/sec (Leak Current 0.5mA)
|
Operating Life
|
6,000 times
|
* Action temp. and reset temp. can be set up depend on customer’s request
Honest-Well Bimetal thermal switch T24 Series –
We can customize this bimetal thermostat according to client’s needs. This snap action temperature switch in three single-pole, single-throw (SPST) switch actions:
Automatic Reset – either open or close its contacts on temperature rise.
Manual Reset – Available with contacts that open on temperature rise. The contacts must be reset by pressing the button after the device cools down.
One shot – Available with contacts that open on temperature rise, and which never reclose unless the ambient temperature drops below -35°C.
For clients who wish to have action temperature above 180°C, we’d recommend our ceramic thermostat H2 series.