WY-S series(Manual)

Overview

Adjustable capillary thermostat.
Manual Reset Heat-Breaker for Electric Water Heater,etc.
Diameter for bulb sensor – between 3~10mm
Standard: 3mm for stainless steel sensor
5mm for copper sensor
Capillary length: min. 300mm.
♦WY-S :to prevent dry heating,
Max. current : 30 Ampere, Max. temperature : 140C

Details

* Below temperature calibration is for reference, which should submit to genuine drawing and production.

 

Type

Operation Temperature (° C )

Switch form

Max Temp of Sensor

(° C )

Capillary tube length(mm)

OFF

DIFF

WY-S3

110 ± 6

Manual Reset

DPST

150

1250

WY-S5

95 ± 5

Manual Reset

DPST

150

400

WY-S15

103.5 ± 6.5

Manual Reset

DPST

150

400

WY-S19

114 ± 6

Manual Reset

DPST

150

400

WY-SA

103.5 ± 6.5

Manual Reset

DPST

150

400