Overview

(1) CONTACT TYPE : Contact Opens When Temperature Rises To Set Point (Normally Closed)
(2) RACKET TYPE : Brass round stud mounting
(3) TERMINAL ORIENTATION : Horizontal
(4) TERMINAL SIZE: Amp#250 TAB ( 6.35mm x 0.8t mm )
(5) Manual Reset

Details

*Electrical Rating: 15A/125V AC
*Operation Temp: 40℃~205℃(UL/CUL)
*Differential:10K~65K
*Calibration Method:1℃/min. Air circulation furnace
*Temp. Tolerance: ±3K / ±5K
*Heat Durability: 180℃*2Hr MAX.
*Circuit Resistance:50 mΩ MAX.
*Insulation Resistance: 100MΩ min. at DC 500V
*Dielectric Strength:AC1000V for One Minute or AC 1800V for One Second(Leak current:0.5mA)
*Operation life: 6,000 cycles

 

Honest-Well Bimetal thermal switch T24 series-
We can customize this bimetal thermostat according to client’s needs. This snap action temperature switch in three single-pole, single-throw (SPST) switch actions:

Automatic Reset – either open or close its contacts on temperature rise.

Manual Reset – Available with contacts that open on temperature rise. The contacts must be reset by pressing the button after the device cools down.

One shot – Available with contacts that open on temperature rise, and which never reclose unless the ambient temperature drops below -35°C.

 

For clients who wish to have action temperature above 180°C, we’d recommend our ceramic thermostat H2 series.