Overview
TRS-Thermal Reed Switch:
Magnet sensing temperature switch
The action temperature (-40℃~130℃)can be chosen freely and the action temperature accuracy is ±1℃, ±2℃ and ±2.5℃.
Details
Working principle:
TRS series temperature sensing switch is to make use of ferrite soft magnet temperature sensitive material and hard magnet material as well as dry reed pipe. It is a new type temperature sensor made based on the principle that ferrite soft magnet material will lose magnet near curie temperature, make the flux passing through dry reed pipe change remarkably so as to make the dry reed pipe connect or close. It has advantages of accurate action temperature, less temperature difference for action resumption, high speed, long service life and explosion resistance etc., thus it is widely used in temperature control and super-temperature protection of electric rice cooker, electric water heating, electric vacuum flask, electric shower, refrigerator, air conditioner and other products as well as cold starting, hot starting and water temperature control of automobile and overheat protection of power supply and machinery equipment.
Performance
Item
|
Classification
|
Specification
|
Measuring condition
|
Action temperature
|
Disconnection temperature
|
70±2℃
|
Temperature rise or temperature fall speed shall be lower than 0.5℃/min
|
Connection/ disconnection temperature difference
|
Between 2~6℃
|
||
Interface of dry reed pipe
|
Max. voltage
|
250V.AC
|
The dry reed pipe shall be measured separately
|
Max. current
|
0.7A.AC~1.0A
|
||
Max. capacity
|
70W.AC
|
||
Interface resistor
|
150mΩ以下
Below 150mΩ
|
||
Insulation resistance
|
100MΩ以上
More than 100MΩ
|
DC500A, between lead and metal shell
|
|
Voltage resistance
|
1500V.AC.5mA/min
|
The voltage resistance between lead and metal shell shall be measured with voltage resistance measuring instrument.
|
|
Tension resistance
|
More than 10N
|
Intensity between lead and main body
|